Biotech Explained · Regenerative Medicine

Cell Culture Basics: Core Techniques for Feeding, Passaging and Counting Cells

By Helen Venturi · · 9 min read

Cell Culture Basics: Core Techniques for Feeding, Passaging and Counting Cells

Cell culture means keeping cells alive and dividing outside the body, in plastic flasks and dishes, under conditions that imitate the tissue they came from. It sits underneath drug screening, vaccine and antibody production, cancer biology, stem cell research and the cell therapies that are now approved medicines. The techniques can be learned in a few weeks. The discipline to do them the same way every time takes longer.

This guide covers the core cell culture techniques for adherent mammalian cells, the usual starting point: reading a culture, feeding it, passaging it, counting it and spotting trouble early.

What cells need

Condition Typical setting for mammalian lines Why
Temperature 37 °C body temperature
Gas about 5 % CO2 in humidified air CO2 balances the bicarbonate buffer in the medium to hold pH near 7.4
Humidity a water pan in the incubator stops the medium evaporating
Medium a basal medium such as DMEM or RPMI 1640, plus serum or defined supplements sugars, amino acids, vitamins, salts, growth factors
Surface tissue-culture treated plastic adherent cells need a surface to attach to and spread on
Sterility a biosafety cabinet and aseptic technique antibiotics are no substitute for clean handling

Most media contain phenol red, a pH indicator, so the color of a flask tells you something before you open it. Red to orange-red is right. Yellow means acid: the culture is dense and needs feeding or splitting, or bacteria are growing. Pink-purple means too alkaline, often because the flask spent too long outside the incubator and lost CO2.

Adherent cells grow attached to the plastic as a single layer, called a monolayer. Suspension cells, including many lines derived from blood, float in the medium and are split simply by dilution. Primary cells come straight from tissue and divide a limited number of times; continuous cell lines have adapted to divide indefinitely. Stem cells, including iPS cells, usually need coated surfaces and specialized media on top of the basics here.

What you need

  • A Class II biosafety cabinet, a CO2 incubator and an inverted microscope
  • Pre-warmed complete medium, PBS without calcium and magnesium, and trypsin-EDTA
  • Serological pipettes with a controller, plus micropipettes and sterile filter tips
  • 15 mL conical tubes and a benchtop centrifuge with a swing-out rotor
  • A hemocytometer, 0.4 % trypan blue and a hand tally counter
  • 70 % alcohol, gloves, a lab coat and biohazard waste

The routine at a glance

How often Task
Each working day look at every flask under the inverted microscope: confluence, cell shape, floating debris, medium color
Every 2 to 3 days feed by replacing the medium
At about 70 to 90 % confluence passage (split) into new flasks
Every passage record passage number, split ratio, date and any count
On a schedule test for mycoplasma; authenticate lines by STR profiling on arrival and at intervals

Confluence is the share of the surface covered by cells. Most adherent lines are split before they reach 100 %, because crowded cells slow down, change their behavior and come off in clumps.

Passaging adherent cells, step by step

Warm the medium and PBS to 37 °C, bring trypsin to the temperature your protocol gives, disinfect the cabinet and wipe everything going into it with 70 % alcohol. The handling habits are the ones in our aseptic technique guide.

  1. Check the flask under the microscope and note confluence and appearance in your records.
  2. Remove the old medium with a serological pipette or an aspirator.
  3. Rinse the cell layer gently with PBS without calcium and magnesium, running it down the side wall rather than onto the cells, then remove it. The rinse washes away serum, which contains trypsin inhibitors, and lowers the calcium that helps cells hold on to the plastic and to each other.
  4. Add just enough trypsin-EDTA to cover the layer, often 2 to 3 mL for a T75 flask, and rock the flask to spread it.
  5. Incubate at 37 °C for a few minutes, 2 to 5 for many lines, and watch under the microscope. Cells round up and begin to slide when the flask is tilted. A firm tap on the side helps. Stop as soon as most cells are loose; over-trypsinizing strips surface proteins and lowers viability.
  6. Stop the enzyme by adding complete medium containing serum, roughly two to four times the trypsin volume. Serum-free cultures need a trypsin inhibitor or a dilution and spin instead.
  7. Pipette gently up and down across the bottom of the flask to wash off remaining cells and break up clumps, without making foam.
  8. Transfer the suspension to a 15 mL conical tube and take a small sample for counting.
  9. Spin to pellet the cells, often 5 minutes at about 200 to 300 × g, then remove the supernatant. Centrifuges are usually set in rpm, but cells experience × g, which depends on the rotor radius; the rpm to rcf calculator converts one to the other. On a rotor with a 15 cm radius, 300 × g is about 1,340 rpm. Some protocols skip the spin when the trypsin volume is small and simply dilute.
  10. Resuspend the pellet by flicking the tube and then pipetting gently, and add cells to new flasks at your split ratio (1:5 means one flask's cells spread across five flasks) or at a counted seeding density.
  11. Label each new flask with the cell line, the new passage number, the date and your initials, and return it to the incubator with the cap vented as the flask type requires.

Counting with a hemocytometer

  1. Mix the cell suspension well, then combine 10 µL of it with 10 µL of 0.4 % trypan blue. A 1:1 mix gives a dilution factor of 2.
  2. Clean the hemocytometer and its coverslip with 70 % alcohol, dry them, and seat the coverslip over the chambers.
  3. Load about 10 µL at the edge of the coverslip and let capillary action fill the chamber. Don't overfill, and avoid bubbles.
  4. At 10x, find the grid and count the four large corner squares. Live cells look bright and clear; dead cells take up the blue dye.
  5. Use one rule for cells sitting on the lines: count those touching the top and left borders, skip those touching the bottom and right.
  6. Keep your eyes on the grid and click a tally counter for each cell, one count for live and one for dead.

Each large corner square of an improved Neubauer chamber is 1 mm by 1 mm with a depth of 0.1 mm, so it holds 0.1 µL, or 10^-4 mL. That gives the standard formula:

cells per mL = (cells counted / squares counted) × dilution factor × 10,000

Count soon after mixing. Healthy cells left in trypan blue for too long start to take up the dye, and viability reads falsely low.

Worked example: count, then seed a flask

Four corner squares counted after a 1:1 trypan blue mix:

Square 1 Square 2 Square 3 Square 4 Total
Live (clear) 52 47 55 50 204
Dead (blue) 6 4 5 5 20
  • Mean live cells per square: 204 / 4 = 51.
  • Live cells per mL: 51 × 2 × 10,000 = 1,020,000, or 1.02 × 10^6 per mL.
  • Viability: 204 / (204 + 20) = 91.1 %.
  • Suppose your protocol seeds a T75 flask at 1 × 10^4 cells per cm². A T75 has 75 cm² of growth area, so you need 7.5 × 10^5 cells.
  • Volume to take: 7.5 × 10^5 / 1.02 × 10^6 = 0.735 mL, or 735 µL, made up to the flask's working volume with fresh medium.

The check: the four squares should be broadly similar, as they are here. If one square holds far more cells than the others, or the two chambers on the slide disagree widely, the suspension was not mixed well or contains clumps; mix again and recount. Counting a total of a hundred or more cells also makes the estimate less noisy. The hemocytometer calculator takes the same counts and returns cells per mL, viability and the seeding volume. After a few passages, two counts and the time between them give a growth rate in the doubling time calculator.

Spotting contamination

Contaminant What you see Usual response
Bacteria medium cloudy and often yellow within a day; tiny moving dots between cells at high power discard the flask, clean the incubator if it spread
Yeast round or oval particles, sometimes budding in chains; cloudiness later discard
Mold thread-like filaments or fuzzy floating clumps discard, check the incubator and water pan
Mycoplasma usually nothing visible; cells may grow slowly or look grainy test by PCR or DNA stain, quarantine, replace from clean stock
Another cell line cells that look or behave unlike the expected line confirm by STR profiling and check the ICLAC register of misidentified cell lines

Many experienced culture labs keep antibiotics out of routine medium, because they can hide low-level contamination and sloppy technique until the day they stop working.

Common mistakes

  • Letting flasks overgrow. Over-confluent cells change behavior and recover slowly; passage on schedule.
  • Leaving medium in a 37 °C bath for hours. Some components, including glutamine, break down with warmth and time. Warm what you need, when you need it.
  • Too much trypsin, too long, or too much vigorous pipetting.
  • Losing track of passage number. High-passage cells drift, so freeze down early, low-passage stocks and work from them.
  • Handling two cell lines in the cabinet at the same time, or sharing one bottle of medium between lines. Both are classic routes to cross-contamination.
  • Tightening the caps of non-vented flasks in a CO2 incubator, which stops gas exchange and lets pH drift.

Human and other primate cells can carry viruses, so BMBL, the CDC and NIH biosafety manual, recommends BSL-2 practices for them, and OSHA treats human cell lines as potentially infectious under its bloodborne pathogens standard unless they are documented free of bloodborne pathogens.

A mini centrifuge is handy for spinning down reagent aliquots and small samples in microtubes; pelleting cells from a flask still needs the benchtop centrifuge with a swing-out rotor.

FAQ

What does confluent mean?

The proportion of the growth surface covered by cells. A flask at 80 % confluence has about a fifth of its surface still bare. Most adherent lines are passaged before they reach 100 %.

How often should cells be passaged?

It depends on the line and the split ratio. Many common lines are split once or twice a week. The supplier's datasheet gives a recommended ratio and density.

How are cells frozen for storage?

Usually in medium with about 10 % DMSO, cooled at about 1 °C per minute to around minus 80 °C and then moved to liquid nitrogen storage. Thaw quickly at 37 °C and dilute the DMSO promptly.

Why use trypan blue?

Live cells with intact membranes keep the dye out, while dead cells take it up and look blue, so one count gives both concentration and viability.

This explainer is general information, not medical advice. Decisions about treatment, donation or trials belong with a clinician who knows your history.